Hp ux mount iso is an invalid operand
The command netstat -rn shows the network routing tables; the entry lo0 is for the loopback interface. Note To verify or set up any of these prerequisites, you must become the superuser by entering su and the root password at the command prompt, or log in as root. The command prompt changes to the pound sign. Verify the correct patch is installed and configured on the system by entering:.
If the patch is shown to be in the "installed" state, configure the patch by entering:. If the patch is shown to be "corrupt" or "transient," reinstall it by using the swinstall GUI and selecting both reinstall lines under Options. Note Both reinstall lines must be checked or the patch will not be reinstalled.
See registered client. ANSI tape label See standard label tape. The file format may be tar, cpio, or with HP-UX 11i v3, pax, and can be compressed. An archive does not include file system or disk layout information. Archives can be either recovery archives or golden archives.
Recovery archives retain host-specific customizations from the system; golden archives have customizable files reset to the newconfig state. An archive may include the core HP-UX operating system, and may include application software, patches, and global customizations. A file containing the contents of other files, created and maintained by programs such as pax, tar and cpio. The results are written in Ignite-UX configuration file syntax to standard output. AUTO A file that defines default boot behavior.
See hpux 1M and hpux. This can be done at the installation command line with a bootsys command, or it can be scheduled to run at a particular time using the cron daemon.
It provides customized lockdown on a system-by-system basis. See boot 1M. The Itanium-based equivalent is the extensible handler BCH firmware interface. Meant for booting only. Installation is completed using an Ignite-UX server. See bootsys 1M. Bundles are distributed within depots and contain products and filesets.
Ignite-UX typically references software at the bundle level, as opposed to product or product. A report is generated showing those files that have been added, deleted, or changed since the recovery archive was created.
This process loads a new copy of HP-UX onto a system. See gzip 1 and compress 1. It includes default configuration information for the operating system release, user-defined configuration information, and information regarding archives and depots. Used with boot helper config media. Also called a crippled config. D daemon A process that runs in the background and is usually immune to termination instructions. These bundles can be deselected before installation.
It remains viewable even if the device is moved physically. See scsimgr 1M. A directed boot allows boot and installation from an Ignite-UX server on a different subnet without requiring a boot helper. There are two general methods of disk layout: physical-storage layout and logical-storage layout.
VxVM and LVM use logical-storage layout, and use various layout techniques such as mirroring and striping. This term can be version abbreviated to DLVx, where x is the disk layout version number. DSFs are read and written to as ordinary files are, resulting in activation of the associated device. See crashconf 1M. The interface consists of platform related interface EFI information, as well as boot and runtime service calls.
F file system A collection of files and supporting data structures residing directly on a mass storage device or on a virtual or logical disk. The product may be part of a bundle. See sd 5. G gateway The IP address of a system that routes forwarded traffic to a non-local network. A gateway IP address is usually associated with a router. See archive. Use as a common configuration to install systems. See gzip 1. Loads the kernel and starts HP-UX.
The bootstrap loader may also load other LIF content it needs to operate. See hpux 1M. See ignite 5. It is loaded and executed after self-test and initialization have completed successfully. See isl 1M. ISL See initial system loader. It is used to customize all or part of the operating system installation on the client before an installation or recovery.
This command is not invoked from the command line. The LIF file is included in boot content and in install content. See lif 4. See logical volume manager. See lvm 7. This refers to an end storage device such as a disk, tape, floppy, or CD. This is the unit itself and does not represent the path to the unit.
The first path element path is , followed by a virtual bus instance and a logical unit number. It is identical in format to a path legacy hardware path up to the HBA.
After the HBA, additional addressing is represented in hexadecimal format. Lunpath hardware paths are part of the agile view introduced in HP-UX 11i v3.
Used to uniquely identify a network interface connected to a local area network. The tape will contain boot and installation components, but not a recovery archive. It is a single large file in the HP-UX operating system that is written to the medium and used for installation or recovery.
Files in a newconfig state contain no information about the personality of the system. Allows a client to perform transparent file access over the network. It allows access from any system to any system with a single user identification and password. O offline diagnostic Diagnostic utilities stored in the boot area or service partition able to run without the operating environment system.
ODE 38 Glossary You must select these bundles before installation. Ignite-UX is an example of an optional software bundle. P partition A portion of a disk device that appears to volume managers, file systems, and other OS software as a disk device.
Partitions allow different portions of a disk to hold content needed for boot, OS file systems, diagnostic tools, and other information.
Ignite-UX uses pax to produce tar, cpio, and pax formatted archives. See pax 1 ,tar 1 , and cpio 1. It can either display the original manifest, or gather information about the current system when it runs. RSA key fingerprint is a:6aa9:efba:7a:ce:af0:aa. Warning: Permanently added ' Import the vg in second node. Warning: A backup of this volume group may not exist on this machine.
Disable automatic VG Activation. Set up trusted hosts within cluster systems. Do the same in second node. Looking for other clusters Writing cluster data to cmclconfig. Edit Cluster details. Time out parameters etc. Verify configuration file. Begin cluster verification Checking cluster file: cmclconfig. Checking nodes Use the cmapplyconf command to apply the configuration. Apply configuration in both nodes. Completed the cluster creation. Run the cluster. Gathering network information.
Waiting for cluster to form Cluster successfully formed. Check the syslog files on all nodes in the cluster to verify that no warnings occurred during startup. Verify cluster is running. Package configuration. Create package configuration files. The package template has been created. This file must be edited before it can be used.
Package control script is created. Edit Package configuration file. Others default you may need to change them depending on your requirement. Edit package control script. Verify configuration. Begin package verification Checking existing configuration Add package to cluster.
Adding the package configuration for package XClock. The Online JFS product has come a long way over the years. The current Back to top When I run my script remotely using ssh, it completes, then hangs. Deleting the line is simpler, but not always desirable. Back to top My syslog is far too big to edit vi. Back to top Can I know ahead of time if the installation of a patch set will require a reboot of the system?
Yes, you can. However, if you are researching a problem and find that you must download more than one individual patch, you may find yourself wondering what you just got. First, load all the individual patches into a single depot, either newly created or already existing.
Then, Generated with www. If you have a disk failure, the replacement disk will should have the same WWID as the original disk. I have not used this technique, but it looks like their 2 commands would do the same as the single command that I used.
If the system creates another device file for the replacement disk, then the second command should clean up nicely. Then, it removes the new device file, or maybe simply renames the new file name to the original file name. Back to top Can I disable a swap device without rebooting my system? Prior to As of HP-UX If your system does not have this command try man swapoff you can download the SwapoffEnh bundle from the HP software depot at: software.
HP-UX Back to top I just updated my system to There is a new option to the vgimport command in HP-UX Run the utility with no parameters to get its usage.
Such software is available both as freeware and as a purchased product. If you will be updating more than one system, it would be wise to copy the ISO files to an NFS server that is available to all systems to be updated. Mount the first ISO image file. Refer to the question below for the details on how to do this. Using the console port, run update-ux and specify the mount point as the source, eg. When prompted by update-ux, in another telnet session, mount the next ISO image file to the same mount point.
Note that update-ux will, by default, update the OE that is currently installed. If you want to add additional software from the application media, use swinstall using the ISO technique described above and below. One option is to burn the. However, there is another method if access to a DVD writer Generated with www. Be aware that the depot may not be at the top level directory. Verify with swlist. The sam utility provides a facility to save and restore the entire lp configuration.
To do this outside of sam, use the following command sequence. The command is mc and takes its parameters from the command line.
That means that you can create a script to load the first tape in an autoloader and use tar, for example, to copy files to that tape, then change to the second tape and copy more files. However, because the basic tape utilities such as tar and cpio do not handle an end-of-tape condition gracefully you have to manage the amount of data transferred to each tape in your script.
You will have to make sure that each invocation of a tar command does not exceed the capacity of the tapes in the autoloader. The in-line comments indicate the purpose of each command. Refer to the mc man page for more command line parameters.
These parameters allow you to check the status of the autoloader as well as determine the number of tapes currently loaded in the magazine. Back to top How do I keep users off my system when I want to do maintenance? When it is time for system maintenance and you must keep users from logging on, HP-UX When that file exists, new users are inhibited from logging on with a display of the contents of that file. When that file does not exist, no such restrictions are enforced.
When patches are installed using the swinstall command, the installation process goes through several steps. Near the end of the process, patch filesets are configured, which is their final state.
If the installation process is aborted, then patches can be one of several other states as well. Filesets in other states should be removed and re-installed. Back to top I just bought a new HP cell based server and the 2 cells came configured as 2 partitions. The system must have come along with sufficient hardware to have 2 nPars, such as a second core IO board and extra internal drives.
Partition 0 contains chassis 1 and cell 1. Partition 1 contains chassis 0, cell 0. First, you have to make partition 1 inactive. Log on to that partition as root and issue: shutdown —R —H 0 Note that the options are in upper case.
The second command adds Chassis 0, Cell 0 to partition 0. Finally, partition 0 is rebooted for reconfiguration. The parstatus command can be used at each step to verify the current partition configuration. Back to top How can I make a depot file from an existing depot directory?
You can accumulate patches and software products into a single software depot using the swcopy command, allowing you to install those filesets in a single pass of swinstall.
Back to top I have an old fbackup tape. Back to top How do I wipe a disk clean of all information before removing it from the system? Quite often, system administrators find that they must replace a disk before it fails for upgrade purposes. When that disk contains company sensitive data, the disk should be wiped clean before removing it from the chassis.
When that sensitive data is actually client information, there may be legal requirements to wipe the disk first, HIPAA for example. The following commands were extracted from the ITRC document Refer to the dd man page for further details.
The disk wipe should only be performed after the disk has been successfully de-configured from LVM or any other volume manager. There are times when you must expand the size of a given file system. There are two steps in this process.
First, extend the size of the logical volume using the lvextend command. Keep in mind that the size specified in this command is the new size, not the size increment. Second, you must extend the file system. If you have the luxury of un-mounting the file system, you can use the extendfs Generated with www. Wile the extendfs command does not require that you specify the new size of the file system, the fsadm command does.
It wants the new size specified in JFS blocks. The default value for the JFS block size is The following command can be used to display the value of a particular TCP timing parameter. Other variations of this command will show all the parameters that can be modified by ndd, as well as set new values for these parameters. The nettune command can be used to display and change the value of many network tunable parameters.
The example below will generate a list of all available parameters, with their current, default, minimum and maximum values. Using the nettune command with no parameters generates a brief help screen. There are many good network calculators available on the web.
0コメント